Dimension Tables
| Pump Model | D | F | G | H | J | K | L | M |
| VSS-QD-4A | 4 | 18 | 15.25 | (4) .5625 | 2.5 | 15.5 | 8 | 22.25 |
| VSS-QD-4C | 4 | 18 | 15.25 | (4) .5625 | 2.5 | 18.5 | 6.25 | 22.25 |
| VSS-QD-4E | 4 | 18 | 15.25 | (4) .5625 | 2.5 | 18.5 | 6.25 | 22.25 |
| Motor Frame | Pump Model | 1750 RPM HP | 1150 RPM HP | E |
| 140TY | ALL | 1 THRU 3 | .75 THRU 2 | 37 |
| 180TY | ALL | 5 THRU 7.5 | 3 THRU 5 | 38 |
| 210TY | ALL | 10 THRU 20 | 7.5 THRU 10 | 45 |
| 250TY | ALL | 25 THRU 40 | 15 THRU 25 | 50 |
| Pump Model | Simplex or Duplex | Min. Pump Removal Hole Size | Min. Hinged Door Size (Type Q,K, J) | Min. Square Pit Size | Min. Round Pit Dia. |
| VSS-QD-4A | Simplex | 16 x 22 | 24 x 24 | 24 x 36 | 42 |
| VSS-QD-4A | Duplex | 40 x 22 | 42 x 42 | 42 x 36 | 54 |
| VSS-QD-4C and 4E | Simplex | 20 x 26 | 30 x 30 | 24 x 42 | 42 |
| VSS-QD-4C and 4E | Duplex | 44 x 26 | 30 x 48 | 42 x 42 | 54 |
1. All dimensions are in inches unless otherwise noted.
2. Dimensions shown are not to be used for construction purposes unless certified.
3. Pit sizes and opening sizes are minimums. Actual sizes must be determined by job conditions.
4. Guide rails must be installed in perfectly vertical position. Use plumb line to correctly position the pump base.
5. Pump discharge check valves and gate valves should be installed on horizontal or 45 inch lines. Installation on vertical lines is not recommended.
6. The VSS-QD guide rail is an ASTM Std. 4 inch wide-flange beam (4 inch H-column).
2. Dimensions shown are not to be used for construction purposes unless certified.
3. Pit sizes and opening sizes are minimums. Actual sizes must be determined by job conditions.
4. Guide rails must be installed in perfectly vertical position. Use plumb line to correctly position the pump base.
5. Pump discharge check valves and gate valves should be installed on horizontal or 45 inch lines. Installation on vertical lines is not recommended.
6. The VSS-QD guide rail is an ASTM Std. 4 inch wide-flange beam (4 inch H-column).
CONTROLS: The recommended control arrangement for VSS-QD pumps is the Submers-a-bulb control (see SBS) which includes on-off mercury bulbs, high water alarm, temperature sensor cut-out, moisture sensor alarm and automatic alternator for duplex units. Float switch controls are also available.