Download Brochure Download O&M Print EMail


cad - cru-cch-specifications_29a.gif


Dimensions Table

Unit NumbersTank Cap. Gal.Tank Shell SizeACGHDrain
CCH-210 THRU CCH-10801414x182926211
CCH-1510 THRU CCH-20802618x243732211
CCH-2510 THRU CCH-30803318x284137311
CCH-4010 THRU CCH-40804518x365046311
CCH-5010 THRU CCH-65806322x36504631.251
CCH-7510 THRU CCH-1008010024x48665941.251
CCH-15010 THRU CCH-1508015030x48686141.51.25


Variable Dimentional Table

Tank Dia.PumpBDEF
14CC29222522
14CG35252724
14CK41283229
14CKH41283229
18CC29242926
18CG35273128
18CK41303633
18CKH41303633
22CC29263330
22CG35293532
22CK41324037
22CKH47354037
24CC29273632
24CG35303834
24CK41334339
24CKH47364339
30CC29304238
30CG35334440
30CK47394945
30CKH47394945


Equivalents Table

1,000sq. ft. E.D.R.=240,000 BTU per hr.
1,000 sq. ft. E.D.R.=247 Ibs. Water Evap. per hr.
1,000sq. ft. E.D.R.=.5 gal. Water Evap. per min.
1 sq. ft. E.D.R.=240 BTU per hr. (Steam)
1 sq. ft. E.D.R.=150 BTU per hr. (Hot Water)
1 sq. ft. E.D.R.=.25 lb. Water Evap. per. hr.
I Boiler HP.=33,475 BTU per hr.
1 BoilerHP.=34.5 Ibs. Water Evap. per hr. (at 212 degrees F)
1 Boiler HP.=.07 gal Water Evap. per min.
1 Boiler HP.=140 sq. ft. E.D.R. (Steam)
1 Boiler HP.=222 sq. ft. E.D.R. (Hot Water)
1lb. P.S.I.=2.31 ft. of Water
1lb. P.S.I.=2.04 ins. of Mercury
1lb. P.S.I.=.068 Atmosphere
1 ft. of Water=.433 Ibs. P.S.I.
1 ft. of Water=.882 ins. of Mercury
1 ft. of Water=.029 Atmosphere


cad - cru-cch-engineering_27a.gif