Features

RECEIVER: Standard receivers are available in steel construction. Receiver top is to be installed flush with finished floor. Receiver covers have all required openings for pumps, controls, and vent connection.

PUMP: Vertical submerged centrifugal type of bronze fitted construction, with balanced bronze impeller, stainless steel shaft, vapor seal where the shaft passes through the support plate, raised ball thrust bearing in dust and moisture-proof housing. Renewable bronze sleeve type pump bearing protected by a mechanical shaft seal. Pump is flexibly coupled to motor.

MOTOR: Drip-proof, ball bearing, vertical, C-face design, for single phase or 3-phase operation.

FLOAT SWITCH: One for each pump; pedestal mounted on tank cover, with adjustable copper float and brass rod; wired to motor or starter.